Contents:

1. Outside rear view mirror
• Put on gloves to prevent hand injuries.
• When removing with a flat - tip screwdriver or remover, wrap protective tape around the tools to prevent damage to components.
• Take care not to scratch the body surface.
1.Using a screwdriver or remover, remove the front door quadrant inner cover (A).

2.Disconnect the tweeter speaker connector (A).

3.Using a screwdriver or remover, remove the outside rear view mirror cover (A).

4.Disconnect the outside rear view mirror connector (A).

5.After loosening the mounting bolts, remove the outside rear view mirror (A).
Tightening torque :6.9 - 10.8 N.m (0.7 - 1.1 kgf.m, 5.1 - 8.0 lb-ft)

6.To install, reverse the removal procedure.
• Make sure the connector is connected properly.
• Replace any damaged clips (or pin - type retainers).

1. Inside rear view mirror
• Put on gloves to prevent hand injuries.
1.Loosen the inside rear view mirror mounting screw.
2.Push the inside rear view mirror base (B) up to remove the inside rear view mirror assembly (A).

3.To install, reverse the removal procedure.
• Put on gloves to prevent hand injuries.
1.Remove the ECM mirror cover (A).

2.Disconnect the ECM mirror connector (A).

3.Loosen the mounted screws and push the ECM mirror base upward to remove the ECM mirror assembly (A).

4.To install, reverse removal procedure.
• Make sure the connector is connected properly.
• Be careful not to damage the windshield glass.
Hyundai Accent (HC) (2017 - 2022) Service Manual: Starter
- Specification Starter ItemSpecification Rated voltage12V, 0.9 kW The number of pinion teeth10 Performance[No-load, 11.5V]Ampere83.6 A Speed3,500 rpm - Components 1. Screw2. Front bracket3. Reducer assembly4. Lever5. Lever rest6. Magnet switch 7. Satellite gear8. Gasket sheet9. Armature assembly10. Yoke assembly11. Adjust washer12.Hyundai Accent (HC) (2017 - 2022) Service Manual: Repair procedures
- Refrigerant System Service Basics Refrigerant Identification • Do not mix R-1234yf in the vehicle with other refrigerant, such as R-134a and etc. • Use only service equipment that is U.L-listed and is certified to meet the requirements of SAE standards to recover and recycle R-1234yf from the air conditioning system. Do not use service equipment for the other refrigerant, such as R-134a and etc.