CompressorType6VSe12
Oil type & CapacityFD46XG (IDEMITSU) 110 ± 10cc (3.72 ± 0.34oz.)
Displacement126 cc / rev
Pulley type6PK - TYPE
Expansion valveTypeBlock type
RefrigerantTypeR - 1234yf
Capacity480 ± 25 g (16.9 ± 0.88 oz.)

Blower Unit
ItemSpecification
Fresh and recirculationOperating methodActuator
BlowerTypeSirocco pan
Speed stepAuto + 8 speed (Automatic), 7 speed (Manual)
Speed controlPWM (Automatic, Manual)
Air filterTypeParticle filter

Heater and Evaporator Unit
ItemSpecification
HeaterTypeFin & Tube type
TypeTube - Fin 1Way
Mode operating methodCable, Actuator
Temperature operating methodCable, Actuator
EvaporatorTemperature control typeEvaporator temperature sensor
Blower singularA/C Output OFF TemperatureA/C Output ON Temperature
Manual control1 - 3 speed1.0°C (33.8°F)2.5°C (36.5°F)
4 - 5 speed1.0°C (33.8°F)2.5°C (36.5°F)
6 - 7 speed0.6°C (33.1°F)2.1°C (35.8°F)
Full auto control1 - 4 speed1.0°C (33.8°F)2.5°C (36.5°F)
5 - 6 speed1.0°C (33.8°F)2.5°C (36.5°F)
7 - 8 speed0.6°C (33.1°F)2.1°C (35.8°F)

- Tightening Torques
ItemsN.mkgf.mlb - ft
Compressor19.6 - 33.32.0 - 3.414.5 - 24.6
Condenser - Discharge hose8.8 - 13.70.9 - 1.46.5 - 10.1
Condenser - Liquid tube
Compressor - Discharge hose21.6 - 32.42.2 - 3.315.9 - 23.9
Compressor - Suction hose
Expansion valve - Evaporator8.8 - 13.70.9 - 1.46.5 - 10.1

Other information:

Hyundai Accent (HC) (2017 - 2022) Service Manual: Engine Oil

- Replacement     • Prolonged and repeated contact with mineral oil will result in the removal of natural fats from the skin, leading to dryness, irritation and dermatitis. In addition, used engine oil contains potentially harmful contaminants which may cause skin cancer. • Exercise caution in order to minimize the length and frequency of contact of your skin to used oil.

Hyundai Accent (HC) (2017 - 2022) Service Manual: Evaporator Temperature Sensor

- Description The evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator from freezing by excessive cooling. The evaporator temperature sensor has the Negative Temperature Coefficient (NTC). Electrical resistivity of NTC will increase with decreasing temperature and decrease with increasing temperature.

Categories


 
Copyright © 2025
0.0069